Short question · 4 points · Unit 3: Properties of Substances and Mixtures

Cobalt(II) colorimetry

Based on: 2022 AP Chemistry exam, free-response question 6 · same skills and points, new chemicals and numbers

A student measures [CoX2+][\ce{Co^2+}] with a colorimeter. A scan of the solution gives:

Wavelength (nm) 400 450 480 510 540 600 650
Absorbance 0.05 0.21 0.38 0.52 0.40 0.08 0.02
1 point

What wavelength should the student use?

1 point

The student fills a 50 mL graduated cylinder (1 mL markings) with stock solution; the bottom of the meniscus is halfway between the 46 and 47 mL marks. What volume should be recorded?

1 point

Calculate the volume of 0.150 M Co(NOX3)X2\ce{Co(NO3)2} needed to make 50.0 mL of 0.0300 M solution.

1 point

The procedure is: (1) prepare standards by dilution; (2) rinse the cuvette with distilled water; (3) rinse and fill the cuvette with the standard; (4) measure absorbance; (5) repeat 2–4. One standard's point falls below the calibration line. Which step could have been done incorrectly? Justify.

Answer first, then compare. Each guideline shows exactly what earns the point.

Chat on WhatsApp