Buret
Definition A long, graduated glass tube with a stopcock, used to deliver precise, measured volumes of a titrant.
Updated · Aligned to the AP Chemistry Course and Exam Description
In more detail
Burets read to the nearest 0.01 mL, with 0 mL at the top. Rinse it with the titrant before filling, remove air bubbles from the tip, and read the bottom of the meniscus at eye level. Volume delivered = final reading initial reading.
Also called: burette
How to read a buret
- Get your eye level with the liquid. Looking from above or below shifts the reading (this is called parallax).
- Read the bottom of the meniscus, the lowest point of the curved surface, not the edges.
- Read downwards. A buret has 0 mL at the top, so the numbers grow as you go down: the opposite of a graduated cylinder.
- Record two decimal places. The marks are 0.1 mL apart, so estimate the hundredths: 20.37 mL, never 20.4 mL.
Worked example: volume delivered
A buret reads 1.25 mL before a titration and 23.70 mL at the end point. How much titrant was added?
Volume delivered = final reading − initial reading = 23.70 mL − 1.25 mL = 22.45 mL
Keep two decimal places in the answer, because both readings have them. Then use it for moles of titrant: \( n = M \times V \), with \(V\) in liters (0.02245 L).
Lab mistakes the AP exam asks about
| Mistake | What happens | Effect on the calculated concentration of the unknown |
|---|---|---|
| Buret rinsed with water, not titrant | The titrant is diluted, so more of it is needed | Too high (more volume recorded than really needed) |
| Air bubble in the tip that escapes during the titration | The reading drops by the bubble's volume, but no liquid was added for it | Too high (volume recorded is bigger than delivered) |
| Reading the top edge of the meniscus | Every reading is off; it can partly cancel in the subtraction | Small error, but inconsistent readings make it worse |
| Going past the end point | Extra titrant is added after the color change | Too high |
These assume the buret holds the titrant and you are finding the concentration of the solution in the flask.
Buret, pipet or graduated cylinder?
| Glassware | Best for | Typical reading |
|---|---|---|
| Buret | Adding a measured, variable volume (titrations) | To 0.01 mL, e.g. 22.45 mL |
| Volumetric pipet | Delivering one exact volume of a sample | A fixed volume, e.g. 25.00 mL |
| Graduated cylinder | Rough volumes when precision doesn't matter | Often to 0.1 mL or 1 mL |
Check yourself: 3 quick questions
1. The bottom of the meniscus is a little more than halfway between the 12.3 and 12.4 mL lines. What should you record? (A) 12.3 mL (B) 12.4 mL (C) 12.37 mL (D) 12.370 mL
C, 12.37 mL. Marks every 0.1 mL let you estimate one more digit, the hundredths. 12.3 and 12.4 throw away a digit you can read; 12.370 claims one you can't.
2. Initial reading 0.85 mL, final reading 18.40 mL. What volume was delivered?
17.55 mL. Final minus initial: 18.40 − 0.85 = 17.55 mL.
3. A student titrates an acid with NaOH from a buret. An air bubble in the buret tip escapes during the titration. Is the calculated acid concentration too high, too low or unchanged?
Too high. The bubble's volume shows up as "delivered" NaOH, so the recorded volume and the moles of NaOH are too big, and so are the moles of acid they imply.
Want to try it? Run a titration in our titration simulation, or practise Unit 4 questions.
Where it comes up
Related terms
-
Conditioning glassware
Rinsing a buret or pipet with a small amount of the solution it will hold, so that leftover water does not dilute that solution.
-
Meniscus
The curved surface of a liquid in a narrow tube; for water it curves downward, and volumes are read at the bottom of the curve.
-
Titrant
The solution of known concentration that is added from the buret during a titration.
-
Titration
A lab method in which a solution of known concentration is added from a buret to a measured sample until the reaction is just complete, to find the sample's amount or concentration.